Autoclave-sterilizable Items
We are offering a wide variety of new autoclavable items that conform to the voice and needs of the field, such as new autoclavable bio-clean goggles that prevent cloudy lenses that resist fogging up as well as new autoclavable boots with increased durability and safety from the press sole. Goldwin will strongly support our customers' respective manufacturing fields with our unique new product proposals.
Goldwin is researching and developing not only the maintenance of environmental cleanliness in bio-clean rooms but also high-performance products with durability and comfort under the theme contamination control of humans and clothing. With these next-generation product lines and our solutions based on entirely new concepts, we contribute to the cleaning of customers' work environments.
 Autoclavable Goggles
New goggles whose lens surface does not become cloudy even after autoclave-sterilization and maintains its anti-fogging effect.

New Product
PA007G3N
Specifications
  • Grade A and B or higher (Class 100 or higher)
  • The problem of cloudiness with conventional lens due to the anti-fogging finish was solved and the lens resisted becoming cloudy.
  • Improved fit to prevent xenobiotic substances from falling
  • Glasses can be used inside this item
  • We pursued user-friendliness in wearing and removing this item. The new buckle is a polycarbonate one-touch adjuster for the goggles that does not require holding the frame
  • Lenses can be sold separately (Ten lenses/bag)
 Conventional Product 
121゚C x 20 minutes x One autoclave sterilization process
Phenomenon:Clouding
 New Product 
121゚C x 20 minutes x One autoclave sterilization process
Phenomenon:
Slight yellowing
Note 1:
Read the instruction manual carefully before using this product.
Note 2:
Do not forget to clean and sterilize this item after use to stabilize the finishing agent. Sterilizing this item before cleaning could cause the elution of the finishing agent and create cloudy spots.
Note 3:
The sterilizing condition for this item is at heat and humidity of 121゚C for 20 minutes. Any sterilization under conditions other than the above could cause deformation.
Note 4:
The anti-fogging finish agent may elute due to autoclaving. If the agent contacts the skin or gets in the eyes, discontinue use and rinse off, although it is non-stimulating. If the agent contacts the frame, wipe it off.
Note 5:
Repeated sterilization could cause yellowing of the frame and lens, but such changes will not affect use.
 boots with zippers
New Product
PA9650P
  • Maintains grade A and B or higher (Class 100 or higher) cleanliness
  • Our original design where grip performance and flexibility were taken into account.
  • Available in sizes from 22 to 30 cm (1 cm pitch)
Specifications
 Autoclavable shoes
New Product
PA9680P
  • Maintains grade A and B or higher (Class 100 or higher) cleanliness
  • Our original design where grip performance and flexibility were taken into account
  • Available in sizes from 22 to 30 cm (1 cm pitch)
Specifications


This product provides superior durability for autoclaving as before.
 Press Sole
New autoclavable boots with improved durability and safety
Autoclave-sterilizable boots with press soles
A new method of manufacturing the soles enabled a consistent and stable sole shape and manufacture of design. Superior autoclavable boots were based on an innovative original design where grip performance and flexibility were taken into account.
(i) Base area resists cracking
(ii) Corners resist chipping
(iii) Improved nonslip property for water locations
(i) All corners of the block design base area are rounded off to eliminate sharp edges
(ii) All corners of the block design mounting surface are rounded off to eliminate sharp edges
(iii) Deeper grains on the block design mounting surface